Technical specifications Air to water heat pump |
||||
Outdoor unit Hydro indoor unit |
HWS- HWS- |
802H-E 802XWH**-E |
1102H-E 1402XWH**-E |
1402H-E 1402XWH**-E |
Heizleistung | kW | 8.0 |
11.2 |
14.0 |
Power consumption heating | kW | 1.96 |
2.40 |
3.15 |
Energy efficiency heating COP | W/W | 4.08 |
4.66 |
4.45 |
Cooling capacity | kW | 6.0 |
10.0 |
11.0 |
Power consumption cooling | kW | 2.13 |
3.52 |
4.08 |
Energy efficiency cooling EER | W/W | 2.82 |
2.84 |
2.69 |
Dimensions | HxBxT mm | 890 x 900 x 290 |
1340 x 900 x 320 |
1340 x 900 x 320 |
Weight | kg | 63 |
93 |
93 |
Sound pressure level | db(A) | 49 |
49 |
51 |
Compressor | DC Doppel-Rollkolben |
DC Doppel-Rollkolben |
DC Doppel-Rollkolben |
|
Refrigerant | R-410A |
R-410A |
R-410A |
|
Flange (gas-liquid) | 5/8” - 3/8” |
5/8” - 3/8” |
5/8” - 3/8” |
|
Min. piping length | m | 5 |
3 |
3 |
Max. piping length | m | 30 |
30 |
30 |
Mix. hight difference | m | 30 |
30 |
30 |
pre-charged piping length | m | 30 |
30 |
30 |
Power supply | V-pH-Hz | 230-1-50 |
230-1-50 |
230-1-50 |
Technical specifications
Hydro indoor unit |
|||||||||
Hydro indoor unit | HWS- | 802XWHM3-E |
802XWHT6-E |
1402XWHM3-E |
802XWHT6-E |
1402XWHM3-E |
|||
Boost heater | 1 phase 230V 3 kW |
3 phase 400V 6 kW |
1 phase 230V 3 kW |
3 phase 400V 6 kW |
3 phase 400V 9 kW |
||||
Leaving water temperature Leaving water temperature |
°C Heating °C Cooling |
20 - 55 10 - 25 |
|||||||
compatible with | HWS-802H-E |
HWS-1102H-E / HWS-1402H-E |
|||||||
Dimensions | HxBxT mm | 925 x 525 x 375 |
|||||||
Weight | kg | 50 |
54 |
||||||
Sound pressure level | db(A) | 29 |
Technical specifications Domenstic hot water tank |
||||
Domenstic hot water tank | HWS- | 1501CSHM3-E |
2101CSHM3-E |
3001CSHM3-E |
Capacity | liter | 150 |
210 |
300 |
Max. water temperature | °C | 75 |
75 |
75 |
Boost heater | kW | 2.75 |
2.75 |
2.75 |
Power supply | 1-phasig 230V |
1-phasig 230V |
1-phasig 230V |
|
Hight | mm | 1.090 |
1.474 |
2.040 |
Diameter | mm | 550 |
550 |
550 |
Material | Stainless steel |
Stainless steel |
Stainless steel |
Accessories |
||||||||||
Model |
Function |
|||||||||
TCB-PCIN3E | Enable signal for external heater, error signal, compressor operation signal, defrost signal | |||||||||
TCB-PCM03E | Input for external room thermostat, input for emergancy stop |
Heating: | Outdoor temperature 7°C TK, 6°C FK, 35°C Leaving water temperature, ΔT = 5°C |
Cooling: | Outdoor temperature 35°C TK, 7°C Leaving water temperature, ΔT = 5°C |
Refrigerant pipes: | 7,5 m piping lenght and no hight difference between indoor and outdoor unit |
Sound pressure level: | mesured in 1 m distance to outdoor unit |