The product "ESTIA"
Bulletin Home
Bulletin Air to water heat pump
Bulletin The main advantages
Bulletin Technical sophistication
Bulletin System components
Bulletin Technical specifications
Bulletin Application areas
Bulletin Catalogue

ESTIA - Technical data

  
Technical specifications
Air to water heat pump
Outdoor unit
Hydro indoor unit
HWS-
HWS-
802H-E
802XWH**-E
1102H-E
1402XWH**-E
1402H-E
1402XWH**-E
Heizleistung kW
8.0
11.2
14.0
Power consumption heating kW
1.96
2.40
3.15
Energy efficiency heating COP W/W
4.08
4.66
4.45
Cooling capacity kW
6.0
10.0
11.0
Power consumption cooling kW
2.13
3.52
4.08
Energy efficiency cooling EER W/W
2.82
2.84
2.69
Dimensions HxBxT mm
890 x 900 x 290
1340 x 900 x 320
1340 x 900 x 320
Weight kg
63
93
93
Sound pressure level db(A)
49
49
51
Compressor  
DC Doppel-Rollkolben
DC Doppel-Rollkolben
DC Doppel-Rollkolben
Refrigerant  
R-410A
R-410A
R-410A
Flange (gas-liquid)  
5/8” - 3/8”
5/8” - 3/8”
5/8” - 3/8”
Min. piping length m
5
3
3
Max. piping length m
30
30
30
Mix. hight difference m
30
30
30
pre-charged piping length m
30
30
30
Power supply V-pH-Hz
230-1-50
230-1-50
230-1-50

 

  
Technical specifications
Hydro indoor unit
 
Hydro indoor unit HWS-
802XWHM3-E
802XWHT6-E
1402XWHM3-E
802XWHT6-E
1402XWHM3-E
Boost heater
1 phase 230V
3 kW
3 phase 400V
6 kW
1 phase 230V
3 kW
3 phase 400V
6 kW
3 phase 400V
9 kW
Leaving water temperature
Leaving water temperature
°C Heating
°C Cooling
20 - 55
10 - 25
compatible with
HWS-802H-E
HWS-1102H-E / HWS-1402H-E
Dimensions HxBxT mm
925 x 525 x 375
Weight kg
50
54
Sound pressure level db(A)
29

 

  
Technical specifications
Domenstic hot water tank 
 
Domenstic hot water tank HWS-
1501CSHM3-E
2101CSHM3-E
3001CSHM3-E
Capacity liter
150
210
300
Max. water temperature °C
75
75
75
Boost heater kW
2.75
2.75
2.75
Power supply  
1-phasig 230V
1-phasig 230V
1-phasig 230V
Hight mm
1.090
1.474
2.040
Diameter mm
550
550
550
Material  
Stainless steel
Stainless steel
Stainless steel

 

    
Accessories  
Model
Function
TCB-PCIN3E Enable signal for external heater, error signal, compressor operation signal, defrost signal
TCB-PCM03E Input for external room thermostat, input for emergancy stop

 

Heating: Outdoor temperature 7°C TK, 6°C FK, 35°C Leaving water temperature, ΔT = 5°C
Cooling: Outdoor temperature 35°C TK, 7°C Leaving water temperature, ΔT = 5°C
Refrigerant pipes: 7,5 m piping lenght and no hight difference between indoor and outdoor unit
Sound pressure level: mesured in 1 m distance to outdoor unit
english versionsrpska verzija

111